← Tepna preprints

Optical HRV against chest ECG on thirty overnight recordings: near-perfect beat detection, a small rMSSD bias, and a closed-form jitter model that does not hold

Michal Planicka  ·  corresponding author — Tepna Project

PpgDex (raw PPG) · ECGDex (raw ECG) nodes, Tepna physiological-signal suite

Draft v3 · re-cut 2026-10-28 from a committed producer, §2.1 re-cut 2026-11-03 · Supersedes Draft v2 (July 2026, twenty nights) and the four-night Draft v1 · Inputs: 30 paired raw-signal overnight recordings · 100% local, reproducible

Revision note (2026-10-28 — RE-CUT, and one retraction): Draft v2’s figures were measured in 2026-07, on twenty nights, and every one of them predates the PPG fill removal (PPG-ABSENCE-AS-VALUE, DONE 2026-09-21) that stopped in-band zeros standing in for absent optical samples. None of them had a committed producer. Both gaps are now closed: tools/ppi-jitter-vs-ecg.mjs produces every figure in §3.1–§3.3 and Table 2 from the raw captures under today’s code, over 30 nights and 1,961 epochs, and this draft reports what it printed. The descriptive panels survive the re-cut: per-epoch rMSSD bias +4.24 % → +4.20 %, SDNN +2.46 % → +2.60 %, PPI bias +0.01 ms → +0.01 ms, sensitivity and PPV at ceiling in both. The central mechanistic claim does not. Draft v2 reported the model rMSSD²ppg = rMSSD²ecg + k·σ² fitting at per-night R² = 0.964 with k = 2.39; the re-cut reads k = 1.21 and R² = 0.088. Five candidate estimators were searched for the published pair and none produces it — the three denominators the same residuals admit (0.088 increment, 0.227 uncentred, 0.579 against rMSSD²ppg itself), the same equation with its reference coefficient freed (0.672), and the devices’ bare per-epoch rMSSD agreement with no model in it at all (0.649). §3.2’s claim that rMSSD error is fiducial jitter and essentially nothing else is therefore retracted, and §3.2 now reports the refutation and what remains true: jitter is strongly associated with the error (§3.3) but does not account for it in the quantitative form v2 published. Every panel now has a producer. The last one carried from Draft v2 — the epoch-level SQI AUC in §3.4 — was re-cut on 2026-11-04 and does not reproduce either: median within-night AUC 0.763 → 0.863, above chance on 9 of 10 evaluable nights → 26 of 26, exact signed-rank p 0.014 → 2.98 × 10−8, a deviation of 0.100 against a pre-stated ±0.05 band. This one misses in the direction of the gate discriminating better than published, so §3.4’s conclusion now stands on a figure of its own. Both halves of §4’s negative result now have a producer, and neither direction reproduces as published. The channel-combination half (re-cut 2026-11-04) reads a maximum advantage of 1.002× for averaging on foot-to-foot dispersion, where v2 published that every combination loses on both criteria. The fiducial half (re-cut 2026-11-03): the middle-amplitude fiducial reads 4.86 ms against the shipped tangent’s 5.03 ms over 1,363 epochs, a paired median of −0.18 ms where v2 published +0.58 ms. The third now has one, and half of it does not reproduce (§2.1, re-cut 2026-11-03): the RR cross-check re-cuts from 0.47 ms to 0.43 ms, but the template-cross-correlation residual re-cuts from 0.244 ms to 1.85 ms per beat — while the sample-grid control in the same published sentence reproduces to 0.5 %, which is what makes the first figure a finding about the statistic rather than about the apparatus. Everything else is dated 2026-10-28.

Abstract

Background. Draft v1 of this paper compared optical HRV against chest ECG on four overnight sessions and reported rMSSD agreement of −0.6% on the two nights the pipeline's own quality gate trusted; Draft v2 widened that to twenty nights and added a closed-form error model. This draft re-cuts every panel from a committed producer and retracts the model. Data. One subject wore a Polar H10 chest ECG (~130 Hz) and a Polar Verity Sense upper-arm PPG (3 green LED pairs, ~176 Hz) simultaneously; the corpus read here yields 30 paired nights, 2,000 five-minute epochs with a timing pair and 1,961 with an HRV pair (163.4 h). All beats derive from raw signal by the production detectors. Methods. A single global affine time map between the two independent BLE clocks is insufficient — it produces a physiologically impossible negative pulse-transit time — because the devices do not drift at a constant rate and pulse-transit time itself wanders; alignment is therefore re-estimated per epoch. Results. Beat detection is at ceiling: median sensitivity 100.00% (IQR 99.58–100.00) and PPV 100.00%. Pulse-interval timing carries essentially zero bias (+0.01 ms) with a jitter of 6.34 ms (IQR 4.61–8.83). Per-epoch rMSSD runs +4.20% high (per-night median of per-epoch medians; 25 of 30 nights within ±10%, 28 of 30 positive) and SDNN +2.60%, but the night-level spread is wide (mean +12.56%, sd 29.57, limits of agreement −45% to +71%). The central result is a refutation. Draft v2's model rMSSD²ppg = rMSSD²ecg + k·σ² was reported at per-night R² = 0.964 with k = 2.39; re-cut it reads k = 1.21 (IQR 0.44–2.53) and R² = 0.088 (IQR −0.046–0.343), below the theoretical band k ∈ [2,6], and no other denominator (0.227, 0.579), the free two-term fit (a = 1.06, R² = 0.672) or the devices' bare rMSSD agreement (0.649) reproduces the published pair. Part of the reason is structural: within a night the jitter IQR is only 4.82 ms, so σ² has little variance for a per-night fit to explain. What survives is an association, not a law: catastrophic epochs (|ΔrMSSD| > 25%, 14.4% of epochs) carry median jitter 19.2 ms against 5.6 ms elsewhere, and 67% exceed 15 ms against 8% of the rest. Conclusion. Optical rMSSD on this hardware is accurate in the median and unreliable in the tail, and the tail is where the jitter is — but the closed-form budget Draft v2 inverted from this model rests on a k this corpus does not identify, and Table 2 is published as an illustration with its weak fit stated, not as a design target. This is a single-subject method study, not a population accuracy rating.

Keywords: heart-rate variability · rMSSD · photoplethysmography · chest ECG · pulse-rate variability · method comparison · fiducial jitter · failed replication · error budget · inter-device clock drift · consumer wearables

0. Layman overview (delete before submission)

An armband reads your pulse with light; a chest strap reads the heart’s electricity directly and is the trusted “truth.” We wore both to bed for thirty nights and compared them beat by beat. The light sensor finds essentially every heartbeat — it almost never misses one and almost never invents one. But it places each beat with a small timing wobble of about six thousandths of a second, because it is watching a pressure wave arrive rather than the electrical spark that caused it. A common heart-rhythm score comes out about 4% too high on a typical night, which is small, and on two bad nights it is out by twice the true value, which is not. The previous version of this paper claimed the wobble explained almost all of that error — tightly enough (96%) to turn accuracy into one engineering number. Re-measured with code anyone can run, it does not. The wobble explains under a tenth of the error night by night, and four other ways of asking the same question all give middling answers too. What stays true is cruder and still useful: the nights and the five-minute stretches that go badly wrong are the wobbly ones — three times the wobble on the worst stretches — so reducing wobble is still the right thing to work on. We just cannot say how much accuracy a given reduction buys. One person, thirty nights, and an honest retraction: a method result, not a product rating.

1. Introduction

Heart-rate variability from a photoplethysmogram (PPG) is attractive because the hardware is cheap and unobtrusive, but optical pulse timing is a mechanical, downstream proxy for the electrical heartbeat an ECG records directly. The literature's summary of that gap is largely qualitative — pulse-rate variability is “unbiased but noisier” than heart-rate variability — and the engineering consequence is left implicit. The most recent quantitative synthesis (Xu et al. 2026, a meta-analysis of PRV–HRV agreement on RMSSD and SDNN) pools only resting, controlled-condition studies and explicitly warns that its estimates “should not be generalized to sleep … or free-living settings” — which is precisely the setting this paper measures: overnight sleep, on consumer hardware, every epoch reported. This paper closes that gap on real overnight data by asking not whether optical rMSSD is biased but what quantity produces the bias, and then inverting the relationship into a design budget.

What changed since Draft v1, and what Draft v3 retracts. Draft v1 used four nights and reported rMSSD agreement of −0.6% on the two its reference-free gate trusted — n = 2 for the headline, with the gate evaluated on the same four nights that selected them. Draft v2 used 20 nights, reported every epoch that aligned, and the headline agreement got honestly worse (+4.24%). Draft v3 changes the method of the paper rather than its corpus: every published panel is now re-cut from one committed producer run over the raw captures, so a reader can re-run the number instead of trusting it. That re-cut confirms the descriptive figures on 30 nights and refutes the mechanistic one (§3.2). The direction of travel across three drafts is the same each time: the more of the corpus is reported and the more of the analysis is executable, the weaker the claim that survives.

2. Methods

2.1 Devices and the raw-signal principle

One subject wore a Polar H10 chest strap (single-lead ECG, measured 129.94–130.03 Hz) and a Polar Verity Sense optical armband (measured 176.35–176.42 Hz) simultaneously, captured with Polar Sensor Logger. The re-cut reads the corpus rather than a remembered wear count: 1,980 files walked, 54 Verity _PPG.txt captures offered and 50 paired H10 _ECG.txt, merging by date into 30 scored nights over 2026-06-10 → 2026-07-13. The Verity's three PPG channels are three diametrically-opposed green LED pairs time-multiplexed onto one shared photodiode, plus a fourth LEDs-off ambient slot — not three wavelengths and not three photodiodes (FCC INW4J internal photographs; four Polar staff statements in the vendor SDK issue tracker). Streaming raw PPG forces SDK mode, which disables the device's own HR and PPI outputs, so both vendor files are empty by design and every optical beat here is derived from the raw waveform.

ECG R-peaks come from a Pan–Tompkins implementation with sub-sample parabolic refinement. Both validation figures now have producers (re-cut 2026-11-03), and they disagree with Draft v2 in opposite directions. Against template cross-correlation the refined fiducial carries 1.85 ms residual jitter per beat — the median of 48 H10 captures inside this corpus's own 2026-06-10 → 2026-07-13 window, 579,462 beats, by tools/ecg-template-xcorr-residual.mjs. That is 7.6× the 0.244 ms Draft v2 published, and no per-beat reading of the same apparatus reproduces it. The control in the same sentence does reproduce: holding the integer peak index against the identical template, with nothing else changed, reads 2.224 ms — within 0.5 % of the 2.213 ms the bare 7.69 ms sample grid imposes and within 0.2 % of that grid's Δ/√12 bound of 2.221 ms. So the apparatus is sound, and sub-sample refinement buys about 17 % on this detector rather than the order of magnitude Draft v2 implied. The 0.244 ms figure is of the order of the same apparatus's segment-aggregated residual (0.103 ms over 300-beat segments), which is smaller than the per-beat quantity by roughly √n and is not comparable to a per-beat grid bound; that is the likeliest provenance of the carried number, and it is still not a match. The RR cross-check, by contrast, holds: the H10's own *_RR.txt agrees with the detector at 0.43 ms median interval difference (tools/oracle-ecg-firmware-rr.mjs, 91 nights of the same device read corpus-wide rather than in-window, against the 0.47 ms carried). Optical beats come from the production PPGDSP path: per-channel band-pass, TERMA detection with a cadence-adaptive refractory, three-LED consensus (a beat is kept only where ≥2 of 3 channels agree within ±50 ms), and intersecting-tangent foot timing on the reference channel.

2.2 Alignment — why a single global time map is not enough

This is the methodological trap in the study, and it is worth stating plainly because the naive analysis produces confident nonsense. The two devices are independent BLE peripherals with independent crystals, logged by one phone; the phone timestamp is derived from each device's own sensor clock, so same-phone logging does not synchronise them. Fitting one affine map tppg = a·tecg + b over a whole night — offset plus a constant drift rate — yielded a median pulse-transit time of −1 ms (physiologically impossible; the pulse cannot precede the R-wave) and an apparent beat F1 of 0.26, while two nights of the same corpus scored 0.99 under the identical procedure. The failure is not in the signal: restricted to a 20-minute window the same data matches at 1,244 of 1,245 beats with a residual standard deviation of 8 ms.

The cause is that neither the relative clock rate nor the pulse-transit time is constant across seven hours. Alignment is therefore estimated per five-minute epoch: a coarse lag from cross-correlating the two instantaneous-heart-rate series (a slowly-varying signal with no periodicity at the beat interval, so it cannot alias by a whole beat), then a local refinement, then one-to-one beat matching within ±75 ms. Epochs that will not align are excluded by named reason rather than by one summary rule, and every count is in §5: of 2,551 candidate epochs the producer drops 542 for too few paired beats, 0 for no envelope lag and 9 at the jitter floor, leaving 2,000 scored. Because each epoch's lag absorbs the local transit time, the reported pulse-interval bias is near zero by construction and is not evidence about transit time.

2.3 The jitter model

If each optical fiducial carries timing noise of standard deviation σ, that noise propagates into successive-interval differences and inflates rMSSD in quadrature. Writing the measured optical rMSSD as a function of the ECG truth and the jitter gives rMSSD²ppg = rMSSD²ecg + k·σ², with k set by how much fiducial noise the successive-difference operator sees. Fully independent per-beat noise gives k = 6; noise shared between adjacent intervals pulls it toward 2, which is what a foot-to-foot construction predicts since each foot enters two intervals. k is fitted per night by least squares on the epoch series and reported with its distribution, never assumed.

2.4 Statistical treatment

Epochs within a night are not independent. Every inferential statement below is therefore computed per night and summarised across the 30 nights; pooled epoch-level figures appear only as descriptive and are labelled as such. This distinction is not cosmetic — a companion paper (Pooling epochs inverts gate rankings) shows that on this same corpus the pooled and night-clustered analyses rank signal-quality gates in exactly opposite order.

3. Results

3.1 Beat detection is near-perfect; timing is not

Across 30 nights the optical detector finds essentially every ECG beat and invents essentially none: median sensitivity 100.00 % (IQR 99.58–100.00) and median PPV 100.00 % (IQR 100.00–100.00). Pulse-interval bias is +0.01 ms. What the optical arm loses is not beats but timing precision: median jitter 6.34 ms (IQR 4.61–8.83, range 3.74–34.23 across nights).

Table 1. Thirty paired overnight recordings, one subject (H10 chest ECG + Verity Sense armband PPG, raw-signal detectors, per-epoch alignment), re-cut 2026-10-28 from tools/ppi-jitter-vs-ecg.mjs. Values are the median across nights of each per-night median, with the inter-night IQR and range. Two populations, never read against each other: the timing rows are the 2,000 epochs the alignment scored; the HRV rows are the 1,961 of those that also carry a per-epoch HRV pair (163.4 h) — 37 epochs cross a session boundary and 2 were refused by the ECG node, and a merged night's interval series are not concatenable across sessions.
QuantityMedianIQRRange across nights
Beat sensitivity100.00%99.58 – 100.0044.77 – 100.00
Beat PPV (match rate)100.00%100.00 – 100.0044.27 – 100.00
PPI jitter (sd)6.34 ms4.61 – 8.833.74 – 34.23
PPI mean absolute error4.38 ms3.47 – 5.142.93 – 25.97
PPI bias+0.01 ms−0.00 – +0.02−0.50 – +0.23
rMSSD bias (per epoch)+4.20%+1.84 – +6.77−11.3 – +134.8
SDNN bias (per epoch)+2.60%+1.49 – +3.33−2.3 – +62.6

The rMSSD distribution is strongly right-skewed by two nights: 25 of 30 nights fall within ±10% and 15 within ±5%, while two sit at +89.5% and +134.8%. The mean across nights (+12.56%, sd 29.57) is therefore not a useful summary and the median (+4.20%) is reported as primary. The bias is one-signed almost everywhere — 28 of the 30 nights are positive — and that count is reported in place of the signed-rank p the previous draft quoted, because the producer counts nights and runs no test over this panel; a test statistic with no producer is exactly what this re-cut exists to remove. The night-level 95% limits of agreement are wide — −45% to +71% — and that width is dominated entirely by the two outlier nights, which §3.3 accounts for.

3.2 The jitter model does not reproduce — Draft v2’s central result, retracted

Draft v2 fitted rMSSD²ppg = rMSSD²ecg + k·σ² per night and reported a median R² of 0.964 (IQR 0.937–0.989) with k = 2.39, concluding that rMSSD error is fiducial jitter and essentially nothing else. Re-cut from the producer over 30 nights and 1,961 epochs, the same fit reads k = 1.21 (IQR 0.44–2.53) and R² = 0.088 (IQR −0.046–0.343, worst −0.651). A negative R² means the fitted line predicts that night’s increment worse than its own mean does. The fitted k now sits below the theoretical band [2,6] rather than inside it, so the one coincidence that made v2’s k persuasive — a free parameter landing in a band predicted from the interval construction — is gone too.

A published R² is ambiguous, so all five candidates were measured rather than assumed. R² for a fit through the origin depends on the total it is compared against, and this model admits three; the equation itself admits a second estimator; and a reader may simply be looking at the devices’ agreement. None of the five reaches 0.964:

Table 1a. Every quantity a bare “R² = 0.964” could denote, measured on the same 1,961 epochs by tools/ppi-jitter-vs-ecg.mjs. Per-night medians over the 30 nights with at least five epochs.
candidate quantitywhat it asksper-night median
R², increment variancedoes σ² explain the gap between the two devices’ rMSSD²0.088 (IQR −0.046–0.343)
R², uncentred incrementthe same residuals against the raw increment sum of squares0.227
R², against rMSSD²ppgthe most flattering denominator — near-tautological, since rMSSD²ecg alone explains most of rMSSD²ppg0.579 (IQR 0.370–0.727)
R², reference coefficient freedrMSSD²ppg = a·rMSSD²ecg + k·σ² with a fitted, not fixed at 10.672 (a = 1.06, k = 1.07)
r², ppg vs ecg rMSSDno model at all — how much of one device’s epoch-to-epoch rMSSD the other tracks0.649 (IQR 0.302–0.808)

The freed fit is the informative one. Its a reads 1.06 (IQR 0.99–1.17), so v2’s a ≡ 1 constraint costs almost nothing — the model is not failing because it was written too rigidly — and even with both coefficients free the fit explains two thirds of rMSSD²ppg, which is roughly what rMSSD²ecg explains on its own. The σ² term is not carrying the paper’s claim. Pooled across all 1,961 epochs the same model gives k = 2.94 with R² = 0.194 (descriptive only, and the pooled k is the one figure that lands inside [2,6]).

Part of the failure is structural, and that part is not a verdict on the physics. σ² is the fit’s only predictor, so a night can only produce a high R² if its jitter actually varies between epochs. Within a night the jitter IQR is a median of 4.82 ms (range 0.55–29.72), against a between-night range of 3.74–34.23 ms: most nights are nearly constant-jitter, which bounds the achievable per-night R² whether the model is right or wrong. A design that wanted to test this model properly would need jitter deliberately varied within a recording — which is also why the pooled fit, spanning the between-night range, behaves better than the per-night ones. What the corpus can support is the association in §3.3, not a coefficient.

Because the model does not hold, the closed-form budget below is no longer a design target. It is retained, re-cut, and labelled, for one reason: it is the inversion Draft v2 published, and a reader comparing drafts needs to see what the same algebra yields once k is measured rather than assumed. Holding the corpus’s own measured ECG rMSSD fixed and solving for σ:

Table 2. Fiducial-jitter budget implied by the fitted model, inverted from a per-night median k of 1.21 whose own fit explains 8.8% of the increment variance (§3.2), so every row is an illustration of the algebra and none is a validated target, and from the measured corpus reference of 35.4 ms median per-epoch ECG rMSSD — the quantity every percentage here is a fraction of. The median night operates at σ = 6.34 ms, and the status column is a count over the per-night jitter column, not a judgement.
Target median rMSSD biasRequired jitter σStatus
≤ 1%4.57 msneeds a 28% cut from the median night — reached on 6 of 30 nights
≤ 2%6.48 msalready met by the median night — reached on 17 of 30
≤ 3%7.95 msalready met by the median night — reached on 21 of 30
≤ 5%10.31 msalready met by the median night — reached on 23 of 30
fiducial jitter σ (ms) rMSSD bias (%) 010203040 0255075100 model, k = 1.21 (R² = 0.088 — dashed: fitted, not supported) 4.6 ms → 1% 8.0 ms → 3% current: 6.34 ms, +4.2% catastrophic epochs (14.4%): 67% carry σ > 15 ms
Figure 1. The jitter model as re-cut, drawn dashed because it is not supported. The curve is the inversion of the measured per-night median k = 1.21 against the measured 35.4 ms reference, and the same fit explains only 8.8% of the per-night increment variance (Table 1a), so the σ values marked on it are illustrative rather than design targets. The current pipeline operates at 6.34 ms with +4.2% median per-epoch bias (the red marker, which is a measurement and does not depend on the fit). Catastrophic epochs are 14.4% of the corpus and 67% of them carry σ > 15 ms — a majority, not the whole population Draft v2 described.

3.3 Catastrophic epochs are high-jitter epochs, not a separate failure mode

283 of 1,961 epochs (14.4%) carry |ΔrMSSD| > 25%. They are not a distinct pathology: their median jitter is 19.2 ms against 5.6 ms elsewhere, and 67% of them exceed 15 ms jitter against 8% of the remainder — a majority, not the clean separation the previous draft reported, so a 15 ms jitter gate would leave a third of them in place. Draft v2 read this as the same model acting at the extreme; with the model refuted (§3.2) the honest statement is weaker and still actionable: jitter and gross rMSSD error are strongly associated in the tail, and the association is what a gate can act on even though the coefficient is not identified. Practically this means the two outlier nights in §3.1 need no separate explanation, and that any intervention which reduces jitter — or any gate that excludes high-jitter epochs — addresses the whole error distribution at once.

3.4 What this does to Draft v1's confidence-gate claim

Draft v1 reported that the pipeline's reference-free gate was “a near-perfect self-classifier,” having labelled two of four nights trusted and two flagged in exact correspondence with the ECG-measured error. That observation stands and reproduces here — but it is a claim about night-level triage resting on a single binary split of four nights, which is consistent with chance. It is not evidence about epoch-level gating, and the two questions have different answers. At epoch level, evaluated within nights, the shipped per-beat SQI discriminates catastrophic epochs with a median AUC of 0.863 (IQR 0.783–0.941; above chance on 26 of 26 evaluable nights, exact two-sided Wilcoxon signed-rank p = 2.98 × 10−8 at n = 26, W⁺ = 351) — good, but not “near-perfect,” and materially short of what the v1 phrasing implies. That panel now has a producer, and the carried figure does not reproduce (tools/ppi-jitter-vs-ecg.mjs --sqi, re-cut 2026-11-04 over the same 30 nights and 1,961 of 1,961 epochs as §3.1–§3.3, ranking the node’s own per-beat SQI against §3.3’s own |ΔrMSSD| > 25 % label; four of the 30 nights are excluded by name for carrying no catastrophic epoch, because an AUC is undefined when a class is absent and 0.5 would read as a measurement): the criterion stated before the run was that the re-cut median sit within ±0.05 of the published 0.763, and the run reports FAIL at a deviation of 0.100. Draft v2 published 0.763 (IQR 0.645–0.791; 9 of 10 evaluable nights; p = 0.014). The miss runs in the direction of the gate discriminating better than published, on 26 evaluable nights rather than 10 and on post-removal bytes — so the conclusion drawn from the panel survives while its number does not: 0.863 is still not “near-perfect.” The p is enumerated exactly rather than approximated, and at this n it is the smallest value the two-sided null can take, because every evaluable night ranked above chance and W⁺ is therefore at its maximum. The full gate comparison, including a methodological hazard that inverts the ranking entirely, is the subject of the companion paper.

4. Discussion

Three conclusions follow, and the second is the opposite of Draft v2’s. (1) The optical arm’s weakness on real overnight data is not beat detection — sensitivity and PPV are both at ceiling across 30 nights — but fiducial timing precision. Effort spent finding more beats is misdirected; effort spent locating them more precisely is not. That conclusion needs no model: it rests on the measured 6.34 ms jitter beside a 100% match rate. (2) The accuracy question does not collapse to a single scalar. Draft v2 claimed it did, on a per-night R² of 0.964, and that fit does not reproduce: 0.088 on the same equation, and no more than 0.672 under any of the four alternative estimators in Table 1a. Jitter remains the best single predictor the corpus offers, and the tail association in §3.3 is strong, but a designer cannot be told what a given jitter reduction buys in rMSSD accuracy — and this corpus structurally cannot tell them, because within a night jitter barely varies (IQR 4.82 ms). Establishing or refuting the model needs a protocol that varies jitter deliberately within a recording, which is a different experiment, not more nights of this one. (3) The corpus-honest agreement figure (+4.20% per-epoch median, mean +12.56% with limits of agreement −45% to +71%) is both far worse than the selected-best-nights figure Draft v1 reported (−0.6%) and far better than its own tail suggests. Reporting the median without the tail overstates what a wearable delivers; reporting the tail without the median understates it. Both belong in any accuracy statement, and this revision exists partly to correct the first draft’s omission of the second and the second draft’s over-reading of the mechanism.

A negative result worth recording, both halves of it now re-cut from a committed producer (channel combination 2026-11-04, fiducial 2026-11-03): the two obvious routes to lower jitter were tested on this hardware and neither lowered it. Combining the three LED channels into one waveform — by simple averaging, by the first principal component, or by a maximum-SNR generalised-eigenvalue beamformer — loses to selecting the best single channel, out of sample, on both a spectral criterion and on foot-to-foot interval dispersion; the channels correlate at ρ ≈ 0.99, so there is little independent noise to average away. That half now has a producer, and the published direction does not survive it as stated (tools/ppg-channel-combination.mjs, re-cut 2026-11-04 over 1,774 blocks of 300 s drawn from the 20 longest Verity recordings in the corpus, with channel selection and every combination weight fitted on each block’s first half and scored on its second): the pre-stated bound was that no combination beats selection on either criterion, and the run reports FAIL. Averaging and the first principal component lose on the spectral criterion (0.993×) and win on foot-to-foot dispersion by 1.002× — a jitter median of 25.90 ms against selection’s 26.05 ms, which is 0.15 ms of a 26 ms figure. The beamformer is the one clear loser, at 1.001× spectral and 0.967× dispersion with a jitter median of 35.25 ms and an IQR reaching 99 ms. Two parts of the carried sentence reproduce exactly: the channels correlate at ρ = 0.9987 in the pulse band, and averaging and PCA-1 are one operation on this hardware — the first principal component’s dominant weight is 0.577, which is 1/√3, the equal-weight mean. The substance therefore survives and the wording does not: no combination buys a materially lower jitter, but “loses on both criteria” overstates a dispersion result that is a wash. Read it as 20 recordings rather than the corpus — the producer takes the longest files first, and a validity sidecar was present for 5 of the 20, so validity is UNKNOWN for the other 15 rather than clean. And substituting the middle-amplitude fiducial that the tilt-table literature ranks above the intersecting-tangent point read worse in Draft v2 (jitter 5.02 ms vs 4.44 ms on a matched segment), consistent with both source papers' own caution that the ranking is morphology- and site-dependent. That half now has a producer and its direction does not reproduce (tools/ppi-jitter-vs-ecg.mjs --fiducial, re-cut 2026-11-03 over 1,363 epochs of 17 recordings inside this corpus’s 2026-07-27 → 2026-08-14 window, 3 recordings excluded for want of a paired ECG night and 5 epochs dropped): the shipped intersecting tangent reads 5.03 ms and the interpolated 50 % crossing 4.86 ms, a paired median of −0.18 ms, worse under the 50 % crossing in 387 of 1,363 epochs. The substitution is a wash on this hardware — neither the regression v2 reported nor a route to a lower floor. The mechanism is that the two fiducials differ by a near-constant translation, 83.7 ms median here (IQR 80.9–87.0) against 89.5 ms measured independently on the PAT path over 30 nights, and a jitter read as the sd of matched interval differences absorbs a translation exactly. An estimator that does not absorb it reports that offset under the fiducial’s name: hold one alignment across both arms and the same tool refuses 51 of 57 epochs on one night and reads 22 ms where it reads 5 ms aligned. The jitter floor on this device is therefore not trivially removable, which is precisely why quantifying it is useful.

Limitations. One subject, one device pair. Nothing here supports a between-subject or population claim. The jitter model was fitted across 1,961 epochs as a within-signal physical relationship rather than a between-subject effect, which is why it was reported at all at n=1 — and it failed to reproduce here (§3.2), with part of the failure attributable to the corpus having almost no within-night variation in σ to fit against. So this corpus neither supports the model nor cleanly refutes the physics behind it; it refutes the published claim that the model is established. Every night is quiet sleep, so the motion-regime axis is untested; the two outlier nights show a failure mode but not a graded motion sweep. The ECG reference is itself imperfect, and by more than Draft v2 stated: 1.85 ms per-beat fiducial jitter as now measured (§2.1) rather than 0.244 ms, with 0.43 ms median interval agreement against the device's own RR stream. Against the 6.34 ms measured σ that is roughly 9 % of the variance rather than the fraction of a percent the carried figure implied — still not the dominant term, still un-deconvolved, and no longer negligible. Per-epoch alignment absorbs pulse-transit time by construction, so no transit-time result is claimed. Epochs within a night are correlated and all inference is night-clustered; at 30 nights the night-level intervals remain wide, and two nights dominate the spread. Draft v2 reported a Wilcoxon signed-rank p for the night-level bias; this draft reports the sign count (28 of 30 positive) instead, because the producer computes no test over the night-level bias — its one test, §3.4’s, ranks a different statistic — and a p-value without a producer is exactly what this re-cut exists to remove. Finally, the model was fitted and evaluated on the same corpus — a held-out subject or device remains the obvious next test, now alongside a protocol that varies jitter within a recording.

5. Reproducibility

6. Sample size and where returns diminish

Draft v1 projected that within-subject limits of agreement would stabilise at roughly 25–30 trusted paired nights and that the budget should then shift from depth to breadth. At 30 nights this draft sits inside that window and the projection broadly holds for the DESCRIPTIVE half: the night-level bias interval is ±10.6 percentage points at 95% (from the printed mean +12.56% and sd 29.57 over 30 nights) while the limits of agreement remain wide because two outlier nights dominate the spread. Draft v2 added the observation that the jitter model reached its asymptote far earlier than the agreement interval did, on a per-night R² of 0.964 with a tight IQR. That inverts under the re-cut: the model fit is the weakest panel in the paper (R² = 0.088, IQR −0.046–0.343), and more nights will not fix it, because the limiting quantity is within-night σ variance (IQR 4.82 ms) rather than night count. Additional single-subject nights will narrow the agreement interval slowly and will do nothing for the model. The remaining value is therefore in breadth: more subjects, and above all more motion regimes, since every night here is quiet sleep and the jitter distribution under motion is exactly what a wearable-grade claim would need.

7. References

  1. Companion methods paper: papers/ppg-quality-gate-pooling.html — pooled vs night-clustered evaluation of signal-quality gates on this corpus.
  2. Companion simulation paper: papers/rmssd-equivalence.html — three-detector rMSSD equivalence on shared synthetic beats.
  3. Companion real-data metrology: papers/sigma-no-reference.html — reference-free per-device σ on the same device corpus.
  4. Companion clock study: papers/wearable-clock-drift.html — inter-device timing drift between two consumer wearables logged by one phone.
  5. Task Force of the ESC/NASPE. Heart rate variability: standards of measurement, physiological interpretation and clinical use. Circulation. 1996;93(5):1043–1065.
  6. Pan J, Tompkins WJ. A real-time QRS detection algorithm. IEEE Trans Biomed Eng. 1985;32(3):230–236. doi:10.1109/TBME.1985.325532
  7. Peralta E, Lázaro J, Bailón R, Marozas V, Gil E. Optimal fiducial points for pulse rate variability analysis from forehead and finger photoplethysmographic signals. Physiol Meas. 2019;40(2):025007. doi:10.1088/1361-6579/ab009b
  8. Elgendi M. On the analysis of fingertip photoplethysmogram signals. Curr Cardiol Rev. 2012;8(1):14–25 (TERMA detection). doi:10.2174/157340312801215782
  9. Xu Shiwen, Liu Hao, Liu Zhengliang, Su Peng, Gu Zhuangzhuang. Accuracy of photoplethysmography-derived pulse rate variability compared with electrocardiography-derived heart rate variability: a systematic review and meta-analysis. Sensors. 2026;26(16):5192. doi:10.3390/s26165192 (pooled resting-state agreement on RMSSD/SDNN; explicitly not generalizable to sleep — the gap this paper addresses).
  10. Project documentation: CLAUDE.md (Clock Contract, evidence-grade system), Tepna suite.
v2.37.0